TRANSTECTOR 1101-626 I2R ICP 48VDC Comparison CITEL DS230S-48DC Surge Protective Device (SPD) CITEL DS230S-48DCSurge Protector 1101-626 I2R ICP 48VDC Surge Protector Intended Application System System Voltage48VDC Number of Phases- Conductors2 Wire + Ground ConfigurationDC Power PRODUCT COMPARISON TABLE This page collects publicly available data from ul.com and assembles a side by side reference table for a convenient product cross reference. Manufacturer TRANSTECTOR UL File #E326289E220064 Model DS230S-48DC 1101-626 I2R ICP 48VDC Product Image UL.com Ratings UL CARD UL CARD UL APPROVALRecognized UL 1449 5th Ed.UL 1449 4th Ed. Recognized Isolated Loop Circuit Protector UL MARK SPD Type4CAUL497B Volt (V)48DC48DC AC/DC DC PVDCDC Phasen/an/a Amps (A)n/an/a Ambient Min (C)-40-40 Ambient Max (C)8580 Mode MLV (Vpk) DC+-DC- DC+-G DC--G710 540 560 not tested per UL 1449 not tested UL 1449 not tested per UL 1449 MCOV DC+-DC- DC+-G DC--G65 65 65 not tested per UL 1449 not tested per UL 1449 not tested per UL 1449 In (kA)10- SCCR (kA)n/a- Additional Data Sheet Ratings Surge Current Rating (kA)302.5 Protection CircuitMOV (Thermally Protected)MOV (Thermally Protected) Leakage CurrentYesYes TOV OptimizedNoNo DiagnosticsIndicator & Remote ContactsIndicator Environmental RatingIP20Manufacturer did not specify # of Wires32 Modes of ProtectionCommon Mode Differential ModeCommon Mode Warranty10-years1-years Notes UL 1449 standard covers SPDs for power circuits not exceeding 1000 Vac and for PV applications up to 1500 Vdc. UL 497B standard covers protectors for Data Communications and Fire-Alarm Circuits. Determining the acceptability of an SPD for your UL equipment (for UL 508A Control Panels and All Other UL Listed Equipment) The UL inspector will first consider the SPD type when determining it’s acceptability for a given application or piece of equipment. This will include UL 508A as well as all other UL Listed equipment. The first level compliance is based on the UL Approval (LISTED or RECOGNIZED) of the SPD or UL SPD Type and it’s Suitable Ratings. This means that it has to meet all safety, performance, environmental and electrical system ratings of the application. If any of these criteria are not fully met, it will require a Procedure Description, a File Update and/or Additional Testing. These actions will require additional costs that may be substantial. For this reason, it is in the interest of the specifier to use UL LISTED SPD’s to eliminate any uncertainty or to make sure the UL RECOGNIZED SPD is selected at the time of UL submittal of the equipment. Approval Considerations Table based on UL SPD Type UL MarkUL1449 SPD TypeSuitable RatingsProcedureDescribedFile Update or Additional TestingNotes 1 2YesNoNoThe only requirement is that the SPD must match electrical and environmental ratings of the UL 508A Control Panel. A UL field inspection of the control panel with the SPD installed is required as a part of a standard follow-up service visit. 1CA 2CA 4CA 5YesYesYesYes – All UL recognized SPD’s require a UL engineering evaluation of the SPD’s existing UL1449 E–file. This will result, at a minimum, in a cost to update the UL file and may also require testing that would result in additional costs. UL data is publicly available with a free account at UL.com. The data has been reviewed by our engineering department. From time to time, the applicants UL file (including CITEL's) may become changed or updated at UL.com due to new testing or corrections to a report. At the time of this comparison you will find this information to be accurate to the UL web site. If you find any information requires an update, please bring to our attention and it will be updated immediately. 10108 USA Today Way Miramar, FL 33025 USAContact us to develop a surge mitigation solution for your application www.citel.usWhere to purchase Citel SPD's