Comparison ABB OVR PV T2 40-1500 P Alternate CITEL DS50PVUS-1500/51 ${ITEM_LINK#2179040}<-No Item, #2179040 CITEL DS50PVUS-1500/51DC PV Surge Protector ABB OVR PV T2 40-1500 P DC PV Surge Protector Intended Application System System Voltage1500Vdc PV Number of PhasesDC+. DC-, G Conductors2 Wire + Ground ConfigurationDC PV PRODUCT COMPARISON This page collects publicly available data from ul.com and manufacturers’ web sites then assembles a side by side reference table for convenient product comparisons. Brand ManufacturerCITEL AMERICA INCABB STOTZ-KONTAKT GmbH Location10108 USA Today Way Miramar FL 33025 USAABB, Eppelheimer Str. 82, Heidelberg 69123 DE UL File #E326289E316468 ModelDS50PVUS-1500/51 OVR PV T2 40-1500 P Product Image${ITEM_LINK#2179040}<-No Item, #2179040 UL.com Ratings UL CARD UL CARD SPD Type11CA UL Mark Volt (V)15001500 AC/DC DC PV DCDC PVDC PV Phase-- Amps (A)n/an/a Ambient Min (C)-40-40 Ambient Max (C)8585 Mode DC+-DC- DC+-G DC--GDC+-DC- DC+-G DC--GDC+-DC- DC+-G DC--G VPR (Vpk) DC+-DC- DC+-G DC--G4000 4000 40004000 4000 4000 MCOV DC+-DC- DC+-G DC--G1500 1500 15001500 1500 1500 In (kA)1010 SCCR (kA)10010 Additional Data Sheet Ratings Surge Current Rating (kA)4040 Protection CircuitTMOVTMOV Circuit Diagram Leakage CurrentYesYes TOV OptimizedNoNo DiagnosticsVisual Indicator Remote ContactsVisual Indicator Environmental RatingIP20IP20 Warranty10-years12 months after installation 18 months after shipment "UL.com Ratings" data is publicly available with a free account at UL.com. The "Additional Data Sheet Ratings" are available for free on the manufacturers web site or by submitting a request directly. All the data has been reviewed by our engineering department. From time to time, the applicants UL file (including CITEL's) may become changed or updated at UL.com due to new testing or corrections to a report. In addition, manufacturers may change the data on their web sites. At the time of this comparison you will find this information to be accurate to the UL web site as well as the manufacturers publicly available data. If you find any information requires an update, please bring to our attention and it will be updated immediately. Determining the acceptability of an SPD for UL 1449 Surge Protective Devices and All Other UL Listed Equipment The UL inspector will first consider the SPD type when determining it’s acceptability for a given application or piece of equipment. This will include UL1449 as well as all other UL Listed equipment. The first level compliance is based on the UL Approval (LISTED or RECOGNIZED) of the SPD or UL SPD Type and it’s Suitable Ratings. This means that it has to meet all safety, performance, environmental and electrical system ratings of the application. If any of these criteria are not fully met, it will require a Procedure Description, a File Update and/or Additional Testing. These actions will require additional costs that may be substantial. For this reason, it is in the interest of the specifier to use UL LISTED SPD’s to eliminate any uncertainty or to make sure the UL RECOGNIZED SPD is selected at the time of UL submittal of the equipment. Approval Considerations Table based on UL SPD Type UL MarkUL1449 SPD TypeSuitable RatingsProcedureDescribedFile Update or Additional TestingNotes 1 2YesNoNoThe only requirement is that the SPD must match electrical and environmental ratings. A UL field inspection of the equipment with the SPD installed is required as a part of a standard follow-up service visit. 1CA 2CA 4 5YesYesYesYes – All UL recognized SPD’s require a UL engineering evaluation of the SPD’s existing UL1449 E–file. This will result, at a minimum, in a cost to update the UL file and may also require testing that would result in additional costs. 10108 USA Today Way Miramar, FL 33025 USAContact us to develop a surge mitigation solution for your application www.citel.usWhere to purchase Citel SPD's