CITEL, Surge Protectors for Industrial sites The equipment used in your manufacturing facilities are very sensitive and vulnerable to lightning and switching surges. The cost of fully surge protecting an industrial plant is limited and provides peace of mind that your system will be operational when you need it most. Surge Protection for Industrial Site OBSTA AC MAIN PANEL DLA-48D3 UL497B LISTED - Imax 20kA - In 5kA - Modular LINKING AUTOMATION MSP-VM12 MJ8-POE-C6A Indoor Cat. 6A 10Gb/s rated POE Surge Protective Device & Mounting Hardware Kit CCTV CAMERA DS74US-277Y/G UL TYPE 1 SPD - Imax 75kA - In 20/30kA - Modular Assembly MLPXUVG-277S LED SPD - Imax 20kA - In 10kA - 120-277Vac 2 wire + ground LED LIGHTING AC SUB PANEL MS200-277Y DLA-24D3 UL497B LISTED - Imax 20kA - In 5kA - Modular ACCESS CONTROL DS230S-48DC FIRE ALARM Download Brochure Surge Protection for Industrial Machinery Surge Protection for Industrial Machinery NFPA 70 Article 670.6 (NEC 2020) NFPA 79 Electrical Standard for Industrial Machinery (2018) NFPA 79 Industrial Machinery in a metal workshop The latest release of NEC/NFPA 70 edition 2020 (NEC 2020) has placed a greater emphasis on increasing personnel safety by mandating the use of Surge Protective Devices (SPDs). From 2014 to 2020, the number articles now requiring SPDs has increased significantly for applications ranging from Modular Data Centers, Fire Pumps, Elevators, Critical Power Systems, Dwellings (Dormatories, Homes, Hospitals, Hotels), etc. Threat to industrial machines Various codes and standards possess safety interlock criteria including the American National Standards Institute (ANSI) standards and NFPA 79 for Industrial Machinery. However, until now, these standards have only just begun to address the expanding role that surge protection plays preserving the integrity of equipment and, more importantly, protecting the lives of personnel. A study commissioned by the Fire Protection Research Foundation, “Data Assessment for Electrical Surge Protective Devices”, provides results of a survey of facility managers concerning surge damage. (NFPA 2014) The study shows that 26 percent of facility managers had damage to safety interlocking systems on industrial machines due to surges . The main purpose of these safety interlocking systems is to protect workers and maintenance personnel from contact with exposed live parts and electric shock. Failure of these devices can put personnel at an increased risk of injury. CNC lathe The solution for NFPA 70 and NFPA 79 To make the installation of a Surge Protective Device (SPD) at the industrial machines interlocking safety circuit mandatory which in turn increases the equipments reliability. NFPA 70 Article 670.6 Surge Protection. "Industrial machinery with safety inter-lock circuits shall have surge protection installed.” In addition, the future NFPA 79 is considering the following changes: 7.8.1 Surge Protective Devices (SPDs). "SPDs shall be provided for industrial machinery with safety interlock circuits to protect against the effects of overvoltages due to lightning or switching surges.” as well as 4.5.2 Electromagnetic Compatibility (EMC). "Transient suppression, isolation, or other appropriate means shall be provided where the equipment of an industrial machine generates electrical noise or transients, which can affect the operation of equipment that is on or part of the industrial machine." Selecting an SPD for Industrial Machinery NEC/NFPA 70 require that Surge Protective Devices (SPDs) shall be UL1449 Listed . This means selecting a surge protector is easier than it has ever been. There are only a few choices available for SPDs that are UL Listed for any of the most commonly used surge standards including UL1449 5th Edition, UL497B, and UL497E. Recommended SPD for Industrial Machines LocationEquipmentSystemSurge Protector Model#Link Service EntranceMain Service Panelboard277/480Vac MDS750E-277Y Branch PanelEquipment Panelboard480Vac M50-480D-A Local EquipmentControl Panel480Vac Power Input DS74US-480D Power Supply120-240Vac Power Input DS72US-230S/G 24Vdc Power Output DS220S-24DC Control UnitEthernet Cat 6A MJ8-C6A 4-20mA DLA-24D3 Wireless P8AX09-6G-N/FF Types of machines covered by NFPA 79 TypeDescription Machine ToolsMetal Cutting Metal Forming Plastics MachineryInjection molding machines Extrusion machinery Blow molding machines Specialized processing machines Thermostat molding machines Size reduction equipment Wood MachineryWoodworking machinery Laminating machinery Sawmill machinery Material-Handling MachineryIndustrial robots Transfer machines Sortation machines Inspection/Testing MachinesCoordinate measuring machines In-process gauging machines Packaging MachinesCarton-strapping machines Drum-filling machines Palletizing machines 10108 USA Today Way Miramar, FL 33025 USAContact us to develop a surge mitigation solution for your application www.citel.usWhere to purchase Citel SPD's Standard and Electric Code References for Surge Protective Devices #Title 1NFPA 70 edition 2020, Article 670 Industrial Machinery, 670.6 Surge Protection 2NFPA 70 edition 2017, Article 670 Industrial Machinery, 670.6 Surge Protection 3NFPA 70 edition 2014, “Data Assessment for Electrical Surge Protective Devices” 4NFPA 79 edition 2018, Electrical Standard for Industrial Machinery, Chapter 7, 7.8 Protection Against Overvoltages Due to Lightning and Switching Surges 7.8.1 Surge Protective Devices (SPDs) 5NFPA 79 edition 2018, Annex C, Examples of Industrial Machines Covered by NFPA79 6ANSI C62.41, Low-Voltage AC Power Circuits 7UL1449 4th Edition, Surge Protective Devices 8UL1449 5th Edition, Surge Protective Devices 9UL497B, Surge Protectors for Data Lines and Fire-Alarm Circuits 10UL497E, Antenna Lead-in Conductors 11IEC 61643-11, Low-Voltage Surge Protective Devices - Part 11: Surge Protective Devices Connected To Low-Voltage Power Systems - Requirements And Test Methods 12IEC 61643-21, Low Voltage Surge Protective Devices - Part 21: Surge Protective Devices Connected To Telecommunications And Signalling Networks - Performance Requirements And Testing Methods 13IEC 61000-45, Electromagnetic Compatibility (EMC) - Part 4-5: Testing And Measurement Techniques - Surge Immunity Test 14CSA 22.2 15NOM-001-SCFI, Standard for Electronic Equipment 16NOM-003-SCFI, Electrical Products - Safety Requirements