Toggle Dropdown
Warranty
Terms and Conditions
CITEL
Company History
Specialist in overvoltage protection
Locations
Test Facilities
Service quality
Lightning & Overvoltages
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of surges
The 'Surge Protector' solution
International Standards
Citel's VG Technology
Products
AC Power
DC Power
Dataline
Radio Frequency
GDT
Applications
UL508A
EV Charging
PV Power Plant
Commercial PV
Residential PV
Industrial Sites
Wireless Radio Sites
LED Lighting
Security Systems
Data Centers
Wind Turbine Installation
Resources
Downloads
Learning Center
News
Contact
Log in
Create an account
Online sales for USA only
Product ranges
AC POWER
DC POWER
DATALINE
RF
GDT
AC POWER
PANELMOUNT AC
MDS600-120T-H
- Type 1/2 SPD - Imax 300kA per phase - In 20kA - NEMA Enclosure
MDS600-120T-H
Part Number:
890672
Surge Capacity to 600kA 8/20us Total
Lightning Capacity to 15kA 10/350us per phase
UL1449 Nominal Discharge Current (In) 20kA (All models)
UL1449 Short-circuit Current Rating (SCCR) 200kA (All models)
UL96A Master Label Compliant
Standard Diagnostics - % of protection present, audible, remote, test/mute
Replaceable Modular Design for SPD
Stainless Steel NEMA 4X
Datasheet
ULCertificate_MDS600-120T*(d).pdf
ULCertificate_MDS600-120T_(d).pdf
Tender specifications
Contact Us
Select another reference:
MDS600E-120T
MDS600E-120Y
MDS600E-240D
MDS600E-240DCT
MDS600E-240Y
MDS600E-277Y
MDS600E-347Y
MDS600E-480D
MDS600S-240D
Electrical Properties
Mechanical Properties
Norms
Install
Misc
Schemas
POWER SPD TYPE
UL1449 TYPE 1/2 LISTED
VOLTS
(V)
240/120
AC/DC/DC PV/RF
AC
PHASE
(PH)
1S
AMBIENT MIN
(C)
-35
AMBIENT MAX
(C)
+85
MODES
L-L, L-N, L-G, N-G
VPR
(V)
1800/1200/1200/900
MCOV
(V)
420/210/210/150
IN
15 impulses 8/20µs
(kA)
20
SCCR
(kA)
200
IMAX
8/20µs
(kA)
300
TECHNOLOGY
Multi-TMOV
NETWORK CONFIGURATION
1PH, 3W+G, Split Phase
CONNECTION METHOD
Screw Terminal (4-10AWG)
MOUNTING
FLANGE MOUNT
MATERIAL
Stainless steel
NEMA RATING (IP RATING)
4X (IP67)
FAIL-SAFE BEHAVIOR
Yes, no upstream over current protection required
REAL-TIME DIAGNOSTICS
% of protection present LED, audible alarm and remote contacts. Optional surge counter.
DIMENSIONS
See diagram
WEIGHT
17 lbs
UL STANDARD
UL1449 5th Edition
UL CATEGORY
VZCA, VZCA7, FOKY, FOKY7
UL FILE NUMBER
E326289, E467909
ANSI/IEEE C62.41
Category C 20kV/10kA
ENVIRONMENTAL STANDARDS
ROHS
Wiring type
Screw
Stranded Wire cross section
Min
mm²
5 mm²
Wire gauge
Min
AWG
10 AWG
Torque
Nm
2,6
Torque
in-lbs
20
Operating Temperature
Min
°C
-40 °C
Operating Temperature
Max
°C
85 °C
Operating Temperature
Min
°F
-40 °F
Operating Temperature
Max
°F
85 °F
Operating Relative Humidity
Max
%RH
95
Operating Altitude
Min
Ft
2000 Ft
Operating Altitude
Max
Ft
6500 Ft
Housing/Enclosure material
Stainless Steel
Mounting
wall mount
IP Environmental rating
IP
IP56
NEMA Environmental rating
NEMA
NEMA 4
Installation Location
Indoor / outdoor
Product Dimension
L
mm
7 mm
Product Dimension
H
mm
16 mm
Product Dimension
W
mm
12 mm
Product Dimension
L
In
0.275 In
Product Dimension
H
In
0.629 In
Product Dimension
W
In
0.472 In
Individual Pack
Yes
Storage Temperature
Min
°C
-40 °C
Storage Temperature
Max
°C
85 °C
Storage Temperature
Min
°F
-40 °F
Storage Temperature
Max
°F
85 °F
Waranty
10 Years
×
CITEL
Reference:
MDS600-120T-H
Part Number: :
890672
Or equivalent