DEHN 952 565 Alternate CITEL DS50PVS-1500/51 DEHN 952 565 Comparison CITEL DS50PVS-1500/51 Surge Protectors for EV Charging Station (DC Power) CITEL DS50PVS-1500/51Surge Protector DEHN 952 565 Surge Protector Intended Application System System Voltage1000Vdc Number of PhasesDC+, DC-, G Conductors2 Wires + Ground ConfigurationDC PV PRODUCT COMPARISON TABLE This page collects publicly available data from ul.com and assembles a side by side reference table for a convenient product cross reference. Brand ManufacturerCITEL AMERICA INCDEHN SE Location10108 USA Today Way Miramar FL 33025 USAHans-Dehn-Strasse 1, Neumarkt Bayern 92318 DE UL File #E326289E319777 Model DS50PVS-1500/51DEHN 952 565 Product Image UL.com Ratings UL CARD UL CARD UL APPROVALLISTEDRECOGNIZED UL MARK SPD Type11CA Volt (V)15001170 AC/DCDC - DC PVDC PVDC PV Phase-- Amps (A)n/an/a Ambient Min (C)-40-40 Ambient Max (C)7585 Mode DC+-DC- DC+-G DC--GDC+-DC- DC+-G DC--G VPR (Vpk) DC+-DC- DC+-G DC--G4000 4000 40003000 3000 3000 MCOV DC+-DC- DC+-G DC--G1500 1500 1500 1170 1170 1170 In (kA)1010 SCCR (kA)n/an/a Additional Data Sheet Ratings Surge Current Rating (kA)4040 Protection CircuitTMOVTMOV Leakage CurrentYesYes TOV OptimizedNoNo DiagnosticsIndicator Remote ContactsIndicator Remote Contacts Environmental RatingIP20IP20 # of Wires33 Modes of ProtectionCommon Mode Differential ModeCommon Mode Differential Mode Warranty10-years5-years Notes DC Rating : Direct current DC PV ratings : Direct current for use in photovoltaic applications only Determining the acceptability of an SPD for your UL equipment for UL 508A Control Panels and All Other UL Listed Equipment The UL inspector will first consider the SPD type when determining it’s acceptability for a given application or piece of equipment. This will include UL 508A as well as all other UL Listed equipment. The first level compliance is based on the UL Approval (LISTED or RECOGNIZED) of the SPD or UL SPD Type and it’s Suitable Ratings. This means that it has to meet all safety, performance, environmental and electrical system ratings of the application. If any of these criteria are not fully met, it will require a Procedure Description, a File Update and/or Additional Testing. These actions will require additional costs that may be substantial. For this reason, it is in the interest of the specifier to use UL LISTED SPD’s to eliminate any uncertainty or to make sure the UL RECOGNIZED SPD is selected at the time of UL submittal of the equipment. Approval Considerations Table based on UL SPD Type UL MarkUL1449 SPD TypeSuitable RatingsProcedureDescribedFile Update or Additional TestingNotes 1 2YesNoNoThe only requirement is that the SPD must match electrical and environmental ratings of the UL 508A Control Panel. A UL field inspection of the control panel with the SPD installed is required as a part of a standard follow-up service visit. 1CA 2CA 4CA 5YesYesYesYes – All UL recognized SPD’s require a UL engineering evaluation of the SPD’s existing UL1449 E–file. This will result, at a minimum, in a cost to update the UL file and may also require testing that would result in additional costs. UL data is publicly available with a free account at UL.com. The data has been reviewed by our engineering department. From time to time, the applicants UL file (including CITEL's) may become changed or updated at UL.com due to new testing or corrections to a report. At the time of this comparison you will find this information to be accurate to the UL web site. If you find any information requires an update, please bring to our attention and it will be updated immediately. 10108 USA Today Way Miramar, FL 33025 USAContact us to develop a surge mitigation solution for your application www.citel.usWhere to purchase Citel SPD's